Bleeding your radiators clears trapped air so they heat evenly and your boiler works less. Here is how to do it safely, in the right order, in a few minutes.

On this page
A radiator key held at the bleed valve with a cloth beneath it.

Trapped air can leave the top of a radiator cold. Bleeding releases that air, but first let the system cool and check your boiler's user instructions. If cold spots remain afterwards, the radiator may need a different treatment.

🧰 You'll need

A radiator bleed key (a couple of pounds from any DIY shop, or a flat-head screwdriver for newer valves) and an old cloth or small container to catch drips.

Signs Your Radiators Need Bleeding

You don't need to bleed radiators on a schedule - only when they show the signs. The classic one is a radiator that's warm at the bottom but cold across the top, where the air has gathered.

Before You Start

Air rises, so to bleed effectively you want the system off and the air settled. Doing it with the pump running just stirs everything up.

Bleed a Radiator in Five Steps

01
Locate the bleed valve

It's the small square nipple at the top corner of the radiator, set slightly back. Modern valves take a flat screwdriver instead of a key.

02
Position your cloth

Hold the cloth or container right under the valve to catch the water that follows the air.

03
Turn slowly anticlockwise

A quarter to half a turn is plenty. You'll hear a hiss as the trapped air escapes - don't open it fully.

04
Close it when water comes

Once the hissing stops and a steady stream of water appears, the air is out. Close the valve snugly, but don't force it.

05
Wipe down and move on

Dry the valve and the radiator, then move to the next one that needs doing.

Which Order to Bleed Them In

Order matters more than people realise. Start with the radiator on the lowest floor that's furthest from the boiler, then work your way towards the boiler and upwards. Working from the far, low point back means you push the air out efficiently rather than chasing it around the system. In a two-storey house, that usually means finishing on the upstairs radiator nearest the boiler.

Top Up the Boiler Pressure Afterwards

Bleeding can reduce pressure in a pressurised system. Check afterwards rather than topping up automatically, and follow the boiler manual if a top-up is needed.

01
Check the gauge

Compare the cold reading with the pressure range in your boiler's manual.

02
Follow the boiler instructions

Filling systems differ. Use only the manufacturer's normal user controls; do not open the casing. If you cannot identify the controls or pressure keeps dropping, ask an engineer.

03
Restart and test

Turn the heating back on and feel each radiator - they should now heat evenly from top to bottom.

How Often Should You Bleed Radiators?

There's no fixed schedule - bleed them whenever you notice cold tops or gurgling, and it's worth a quick check at the start of each heating season in autumn. If you find yourself bleeding the same radiator every few weeks, that's not normal: air is getting back in somewhere, which can point to a leak, a failing pump seal, or corrosion creating gas inside the system. That's worth an engineer's eyes.

Still Cold After Bleeding?

Persistent cold spots can have several causes; see why a radiator will not heat up before choosing a treatment. Follow Worcester Bosch's cooled-system bleeding guidance and your own manufacturer's instructions. If the whole system is affected, start with the boiler checklist or check engineer availability.

Find an emergency heating engineer

Enter your postcode - 24/7 cover, no upfront costs.

Get help now